|
|
|
| The Impact of Using A Fully Digital Guide Plate on the Accuracy of the Implantation Site During Immediate Implantation and Restoration Surgery for Anterior Teeth |
| Wu Jianming1, Wu Ying2, Chen Meiling1 |
1. Putian Hanjiang Hospital,Putian,Fujian 351111; 2. Putian City Chengxiang District Hospital Fujian Putian 351100 |
|
|
|
|
Abstract Objective To investigate the effect of full process digital guide plate on the accuracy of implantation site during immediate implantation and restoration of anterior teeth. Method 72 patients who underwent pre implantation of anterior teeth were selected.The patients were divided into an observation group and a control group,with 36 patients in each group(random number table method),as the study subjects.The observation group underwent immediate implantation and restoration of anterior teeth with the assistance of a fully digital guide plate,while the control group underwent immediate implantation and restoration of anterior teeth as a control.Compare the accuracy of the upper anterior tooth implantation site(neck,root tip,axial angle,and depth deviation of the implant),gingival health indicators(bleeding and plaque index),aesthetic effects(red and white aesthetic effect scores),and complications between the observation group and the control group. Result One week after surgery,the observation group had smaller deviations in all aspects of the implant placement site compared to the control group,with statistical differences(P<0.05).The observation group had lower bleeding and plaque index than the control group at 3 months after surgery,with statistical differences(P<0.05).The red aesthetic effect score of the observation group was higher than that of the control group at 3 months after surgery,and there was a statistical difference(P<0.05); There was no statistically significant difference in the white aesthetic effect score between the two groups(P>0.05).There was no statistically significant difference in complications between the two groups(P>0.05). Conclusion The application of fully digital guide plates in immediate implantation and restoration of anterior teeth can improve the accuracy of implantation sites and postoperative aesthetic effects,reduce bleeding and plaque,and do not increase the incidence of postoperative complications.
|
|
Received: 27 April 2025
|
|
|
|
|
|
[1] 谢玲玲,高敏,邱憬,等.数字化静态导板与种植机器人系统辅助无牙颌种植手术的精度分析[J].中华老年口腔医学杂志,2023,21(3):157-162. [2] 成妮,单文汐,温涛,等.计算机辅助设计种植体支持式可摘局部义齿即刻修复下颌Kennedy第二类牙列缺损1例[J].中华口腔医学杂志,2024,59(11):1140-1144. [3] 刘芳,罗田雨,刘书婷,等.种植机器人对前牙美学区即刻种植患者口腔功能与美学效果影响[J].实用医学杂志,2024,40(18):2584-2589. [4] 张维丹,汪婷,刘玉洁,等.3种数字化技术在前牙美学区种植中的精度分析[J].实用口腔医学杂志,2024,40(5):691-697. [5] 李振强,闭艳妲,刘一鸣.以咬合关系为导向的数字化种植导板在牙列缺损患者中的修复效果及对牙齿功能的影响[J].海南医学,2024,35(17):2474-2479. [6] 黄宁,唐小剑,张月.改良盾构术与不翻瓣即刻种植在前牙美学区即刻种植修复中的效果比较[J].哈尔滨医科大学学报,2024,58(3):270-274. [7] 吴倩倩,杜丽娟,范雅儒,等.全程数字化导板即刻种植即刻修复在前牙美学区精准度的研究[J].中国美容医学,2024,33(7):119-123. [8] 关廉,刘雪梅,王俊成,郭斌.数字化外科导板在上前牙即刻种植中的临床应用和精准度评价[J].口腔颌面修复学杂志,2020,21(1):5-11. [9] 于海洋. 数字化导板引导下的显微牙体预备——重新认识到新实践[J].中华口腔医学杂志,2020,55(10):710-715. |
|
|
|